The requirement
A poultry processor ran four portion types on the same shift โ wings, drumsticks, thighs and breast fillets โ at a combined 500 kg/h, with packed output and frequent product changeover.
The configuration
| Item | Specification |
|---|---|
| Freezer | DJL-QF-600A LN2 cabinet |
| Chamber | 900ร1,100ร1,800 mm |
| Loading | Two trolleys per cycle |
| Control | Recipe per product, stored on the PLC |
| Capacity | 600 kg/h rated |
Why a cabinet rather than a tunnel
The hourly output alone would justify a tunnel, but the product mix would not. Four changeovers per shift on a tunnel means four re-tuning events and four periods of unstable temperature; on a cabinet it means selecting a different recipe and loading a different trolley.
The cabinet also fits the packed format: trolleys are loaded at the packing station and wheeled in, which removes a transfer point that was damaging the product on the old line.
What to watch in operation
- Trolley loading pattern โ the gap between trays is what lets cold vapour reach the centre of the load.
- Door discipline: an open door during loading is the largest single nitrogen loss on a cabinet line.
- Recipe discipline: the PLC stores the cycle, but only if the operator selects the right one.
Reference configuration. Rated capacity is the machine rating; output depends on portion size, pack format and loading pattern.
Request a configuration
The more you tell us about the product and the line, the more precise the proposal.