The requirement
A fish processor packed fillets in vacuum bags before freezing. The pack, not the fish, set the freezing time: on the existing air-blast line the centre of a 40 mm pack took over 90 minutes, and the outer fillets were over-frozen by the time the centre arrived.
The configuration
| Item | Specification |
|---|---|
| Freezer | DJL-1000CI immersion tunnel |
| Tunnel | 12,000×1,600 mm |
| Bath temperature | -35°C |
| Cooling capacity | 150 kW |
| Bath liquid | Food-grade, with automatic concentration control |
| Format | Packed product, continuous |
Why immersion
A liquid bath removes heat through the pack far faster than air at the same temperature, so the whole pack freezes through in a fraction of the time and the gradient across it is smaller. The pack surface stays clean, which matters for retail presentation, and there is no glaze step to compensate for surface drying.
The bath concentration control was specified because the plant runs two shifts with wet product entering the line; without automatic make-up, the bath would drift and the dwell time would quietly stretch.
What to watch in operation
- Pack integrity — a leaking pack contaminates the bath and changes its freezing point.
- Bath concentration and renewal interval, logged per shift.
- Liquid recovery at the exit: carry-out is the main make-up cost.
Reference configuration. Capacity is the machine rating at design conditions.
Request a configuration
The more you tell us about the product and the line, the more precise the proposal.