๐Ÿ“ž +86 188 2550 1449 ๐Ÿ’ฌ WhatsApp / WeChat: 18825501449 โœ‰ sales@cryo-freezing.com

Cryogenic Freezing System

Storage, vaporisation, injection and freezer supplied as one sized package, with utilities and layout.

Cryogenic Freezing System

Overview

A freezer is only part of a working cryogenic line. Between the tanker delivery and the frozen product there is storage, pressure regulation, vaporisation, flow control, exhaust and safety monitoring. When these are bought separately, the interfaces are where projects slip and nitrogen is wasted.

We supply the freezing system as one package: the freezer, the liquid nitrogen storage and vaporiser sized to peak demand, the injection and control hardware, and the layout drawing that shows where each item sits and what it needs from site.

What the package includes

  • Freezer โ€” tunnel or cabinet, sized to hourly output and dwell time
  • LN2 storage โ€” vertical or horizontal tank, sized to delivery interval and daily consumption
  • Vaporiser โ€” ambient or electrically heated, sized to peak flow rather than average
  • Injection and control โ€” solenoid valves, flow measurement, recipe control from the freezer PLC
  • Safety โ€” oxygen depletion monitoring, exhaust ventilation, alarms interlocked to the freezer
  • Documentation โ€” P&ID, utility schedule, layout, commissioning record

Sizing the system

Three numbers set the size of everything downstream:

  1. Hourly output and product mass. This fixes the heat load.
  2. Dwell time to target core temperature. This fixes freezer length or chamber volume.
  3. Delivery interval for liquid nitrogen. This fixes tank volume โ€” a weekly delivery and a daily delivery give very different tanks for the same consumption.

Heat load is calculated from the product’s sensible heat, its water content and latent heat, and the heat removed below freezing. Dividing that by the usable enthalpy of liquid nitrogen gives the theoretical consumption; the practical figure is higher because of boil-off during loading, exhaust losses and start-up, and we state both in the proposal so the operating cost is not a surprise.

Cold-vapour recovery

The cold nitrogen vapour leaving the freezer is still well below zero. Where the layout allows, it is routed back over the incoming product or used to pre-cool the tunnel entry. Recovery is the single largest lever on nitrogen consumption after correct sizing.

When a full system makes sense

  • New lines where no gas infrastructure exists on site
  • Plants switching from compressor freezing to cryogenic freezing
  • Projects where the buyer wants one interface for freezer, tank and safety equipment
  • Sites where nitrogen delivery logistics are the constraint rather than freezer capacity

FAQ

Can you supply the freezer only?

Yes. Many customers already have a tank and vaporiser. In that case we need the supply pressure, available flow and pipe size, and we size the freezer to those limits.

Who handles installation?

We supply the layout and utility schedule, and can provide supervision or a full installation package depending on the site. Local electrical and gas work is normally handled by a qualified local contractor, with our drawings as the specification.

How is consumption verified?

At commissioning we run the line at the design product and record nitrogen consumption per tonne over a full shift. That figure, not a catalogue value, becomes the basis for the operating budget.

Request a configuration

The more you tell us about the product and the line, the more precise the proposal.