Overview
In an immersion freezer the product passes through a bath of food-grade freezing liquid held at -35°C in normal operation, down to -70°C when the process calls for it. Liquid conducts heat far better than air — the bath density is roughly 1,100 times that of air and its thermal conductivity about 25 times higher — so the surface of a pack reaches freezing temperature almost immediately and the whole pack freezes through in minutes rather than tens of minutes.
The bath is not a static tank. Pumps circulate the liquid through nozzles at the entry and exit, and the flow field inside the trough is arranged so that every pack sees the same velocity. That is what keeps dwell time predictable from one end of the shift to the other.
Standard models
| Model | Format | Capacity | Bath / tunnel size | Cooling capacity |
|---|---|---|---|---|
| DJL-50CI | Bath | 50 kg/h | 1,000×600×500 mm | 7.5 kW |
| DJL-100CI | Bath | 100 kg/h | 1,400×600×650 mm | 15 kW |
| DJL-200CI | Bath | 200 kg/h | 1,700×600×900 mm | 30 kW |
| DJL-500CI | Tunnel | 500 kg/h | 8,000×1,200 mm | 75 kW |
| DJL-1000CI | Tunnel | 1,000 kg/h | 12,000×1,600 mm | 150 kW |
| DJL-1500CI | Tunnel | 1,500 kg/h | 16,000×1,800 mm | 220 kW |
| DJL-2000CI | Tunnel | 2,000 kg/h | 18,000×2,400 mm | 280 kW |
Process data
| Parameter | Value |
|---|---|
| Bath temperature | -35°C typical, down to -70°C |
| Freezing time | 5–30 minutes |
| Body material | 304 stainless steel |
| Insulation | 150 mm polyurethane |
| Refrigerant | R507 / R404A |
| Refrigeration | Single-compressor two-stage packages |
| Power supply | 380 V / 50 Hz |
| Bath liquid | Food-grade, SGS tested |
Design points
- Flow simulation before fabrication. The trough geometry and nozzle layout are modelled so the bath velocity is even across the width; dead zones are where dwell time drifts.
- Liquid recovery. Liquid carried out on the product is drained, filtered and returned, which is what keeps make-up consumption low.
- Concentration control. On-line monitoring of the bath concentration triggers automatic make-up, so freezing point does not drift over a long shift.
- Moisture management. Surface coating and a vapour barrier on the inner walls reduce condensation on the machine and on the floor around it.
- Hygiene. The bath is food-grade and the circuit is designed for periodic renewal and cleaning without dismantling the trough.
Where it fits
Packed seafood (fish, shrimp, cephalopods), poultry, red meat, prepared dishes and any product where the pack — not the bare product — has to be frozen quickly and evenly. Bare product can be frozen in a bath only where the process allows direct contact with the liquid.
FAQ
Why immersion instead of air or nitrogen?
Because the heat-transfer medium is a liquid. A pack that takes 60–90 minutes in a blast freezer can freeze through in 10–20 minutes in a bath, and the faster the core passes the crystal-growth zone, the less drip loss on thaw.
Is the liquid safe for food?
The bath uses a food-grade liquid supplied with test documentation. Product is packed before entering the bath; the liquid never contacts the food itself.
What maintenance does the bath need?
Concentration check and make-up are automatic. The bath is renewed on a schedule set by loading and product type, and the circulation pumps have service intervals stated in the manual.
Request a configuration